The Bonida H501-06 is a single-point weighing load cell for industrial weighing systems and equipment integration. Verified technical specifications (source catalog page 26):
• Capacity: 150, 250, 500, 1000, 2000 kg
• Rated output: 2.0 ±1% mV/V
• Zero balance: ±1% mV/V
• Creep: 0.02% F.S.
• Non-linearity: 0.02% F.S.
• Hysteresis: 0.02% F.S.
• Repeatability: 0.01% F.S.
• Input impedance: 380 ±15 Ω
• Output impedance: 350 ±1 Ω
• Temperature effect on sensitivity: 0.02% F.S./10°C
• Temperature effect on zero: 0.02% F.S./10°C
• Insulation resistance: ≥5000 MΩ/100 VDC
• Recommended excitation: 5–12 V
• Maximum excitation: 15 V
• Compensated temperature range: -10 to 40°C
• Operating temperature range: -20 to 65°C
• Safe overload: 150% F.S.
• Ultimate overload: 200% F.S.
• Cable: 3 m
• Material: Alloy steel
Public pricing is not displayed. Please submit an RFQ to confirm the required capacity, quantity, integration details and lead time.